GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Purine, 6-benzylamino-, 9-beta-D-glucopyranosyl- (4TMS)

 

Replica Mass Spectra of Purine, 6-benzylamino-, 9-beta-D-glucopyranosyl- (4TMS)

replicalib entry datedetectionmethodspecies
101 December 2003 MS-QuadM[2]Standard
229 November 2003 MS-QuadM[2]Standard
419 July 2007 MS-TOFMDN35Reference Substance
507 September 2004 MS-QuadM[2]Standard
4 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analytePurine, 6-benzylamino-, 9-beta-D-glucopyranosyl- (4TMS)
analyte InChIInChI=1S/C30H53N5O5Si4/c1-41(2,3)36-19-23-25(38-42(4,5)6)26(39-43(7,8)9)27(40-44(10,11)12)30(37-23)35-21-34-24-28(32-20-33-29(24)35)31-18-22-16-14-13-15-17-22/h13-17,20-21,23,25-27,30H,18-19H2,1-12H3,(H,31,32,33)/t23-,25-,26+,27-,30-/m1/s1
analyte mass676.12
chromatogram6087if_29
citation 
authorsBoelling C, Liebig F, Erban A, Kopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date19 July 2007
metabolite roleMETB
retention time (sec)1,882.28
retention index (VAR5 method, n-alkanes C10–C36)3,463.62 (observed)
base peak (m/z)73
maximal intensity377,374
mass-intensity-peaks cardinality445 intensities
minimal m/z45
maximal m/z991
download JCAMP DXSpectrumJcampDx.ashx?id=23e6f683-b1ed-4d07-bc5f-2b593dd921d2
download MSPSpectrumMsp.ashx?id=23e6f683-b1ed-4d07-bc5f-2b593dd921d2

GC-Method

nameVAR5
citationKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
attributetextdetails
deconvolutionChromaTOFOFFSET: "just above noise"; SMOOTHING: 20; PEAK WIDTH: 6; S/N: 2
derivatizationMEOX; TMSMETHOXYAMINATION: 90min at 30°C; TRIMETHYLSILYLATION: 30min at 37°C
detectorMS-TOFm/z = 70-600; scans:20/s; Pegasus III TOF mass spectrometer
extractionwater:chloroform (2:1; v/v) 15min at 70°C
gas chromatographAgilent GC 6890 
ion sourceEI70eV
mass spectrometry instrumentPegasus III TOF mass spectrometer 
metabolic inactivationshock-frozen in liquid nitrogen 
RIALKANEC10, C12, C15, C18, C19, C22, C28, C32, C36
separationGCCOLUMN:5%phenyl-95%dimethylpolysiloxane, 30+10m, ID:0.25mm, DF:0.25µm, 5PDM VF-5ms (Varian, Darmstadt, Germany); PROGRAM:iso1min 70°C, ramp 9°C/min, iso 5min 350°C; FLOW:Helium, 0.6mL/min; INJECTION:1µL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C
protocolpropertyvalue
extractionwater chloroform(2:1; v/v) 15min at 70°C
derivatizationderivatisationMETHOXYAMINATION, 90min at 30°C
derivatizationderivatisationTRIMETHYLSILYLATION, 30min at 37°C
separationIon source temperature250°C
separationColumn length30+10m (analytical column + guard column)
separationColumn inner diameter0.25mm
separationTemperature programisotherm 1min 70°C, ramp 9°C/min, isotherm 5min 350°C
ion sourceelectron ionization70eV
detectorLECO instrument modelPegasus III TOF mass spectrometer
detectorhighest observed m/zm/z = 600
detectorlowest observed m/zm/z = 70
detectorsampling frequency20 scans/s
detectormass analyzer typeMS-TOF
deconvolutionmoving average smoothing20
deconvolutionsoftwareChromaTOF
deconvolutionsignal-to-noise ratio2
RIRetention indexdecane
RIRetention indexdodecane
RIRetention indexpentadecane
RIRetention indexoctadecane
RIRetention indexnonadecane
RIRetention indexdocosane
RIRetention indexoctacosane
RIRetention indexdotriacontane
RIRetention indexhexatriacontane
ChromatographyChromatographyAgilent GC 6890

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 03/03/2025 © 2008-2014 Golm Metabolome Database - All rights reserved
Top