GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

1-Oleoyl-rac-glycerol (2TMS)

 

Replica Mass Spectra of 1-Oleoyl-rac-glycerol (2TMS)

replicalib entry datedetectionmethodspecies
212 May 2005  M[NIST] 
312 May 2005  M[NIST] 
503 November 2010  Schomburg_GC_2010 
401 February 2005 MS-TOFM[6]Reference Substance
4 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyte1-Oleoyl-rac-glycerol (2TMS)
analyte InChIInChI=1S/C27H56O4Si2/c1-8-9-10-11-12-13-14-15-16-17-18-19-20-21-22-23-27(28)29-24-26(31-33(5,6)7)25-30-32(2,3)4/h15-16,26H,8-14,17-25H2,1-7H3/b16-15-
analyte mass500.9
chromatogram3225BF29
citation 
authorsKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date05 October 2004
metabolite roleMETB
retention time (sec)2,414.28
retention index (VAR5 method, n-alkanes C10–C36)2,754.09 (predicted, according to Strehmel, N. et.al)
base peak (m/z)73
maximal intensity999
mass-intensity-peaks cardinality170 intensities
minimal m/z41
maximal m/z598
download JCAMP DXSpectrumJcampDx.ashx?id=3945903e-8c8a-40cd-b46b-275b78a11e48
download MSPSpectrumMsp.ashx?id=3945903e-8c8a-40cd-b46b-275b78a11e48

GC-Method

nameM[2]
citationRoessner U, Wagner C, Kopka J, Trethewey RN, Willmitzer L (2000) Plant J 23, 131-142
attributetextdetails
deconvolutionAMDIS, National Institute of Standards and Technology, Gaithersburg, MD, USADIRECTION:Low to High; WIDTH: 20; SUBTRACTION: two; RESOLUTION: low; SENSITIVITY: low; SHAPE: low
derivatizationMEOX; TMSMethoxyamination:60min37°C; Trimethylsilylation:>45min37°C
detectorMS-Quadm/z = 35-600; scans:2/s; MD 800 Thermo-Finnigan, San Jose, CA, USA
extractionmethanol:water (4:1; v/v); 15min70°C 
ion sourceEI70eV
metabolic inactivationcut; liquid nitrogen; -80°C 
partitioningmethanol fraction of a methanol:water:chloroform (approx. 2:2:1, v/v/v) partitioning 
RIALKANEC12, C15, C19, C22, C28, C32, C36
separationGCCOLUMN:5%diphenyl-95%dimethylpolysiloxane (arylene), 30+10m, ID:0.25mm, DF:0.25microm, Rtx-5SilMS Integra-Guard, #NA (Restek, Bad Homburg, Germany); PROGRAM:iso1min70°C, ramp9°C/min, iso5min350°C; FLOW:Helium, 0.6ml/min; INJECTION:1microL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved
Top