GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Adenosine-5-monophosphate (5TMS)

 

Replica Mass Spectra of Adenosine-5-monophosphate (5TMS)

replicalib entry datedetectionmethodspecies
119 July 2007 MS-TOFVAR5Reference Substance
1130 March 2011  Fiehn_GC_2010 
212 May 2005  M[NIST] 
326 November 2004  M[FAME4090]Standard
1003 November 2010  Schomburg_GC_2010 
401 May 2001 MS-TOFM[EIGTMS]Reference Substance
519 July 2007 MS-TOFMDN35Reference Substance
1230 March 2011  Fiehn_GC_2010 
612 May 2005  M[NIST] 
722 February 2005 MS-TOFM[STR] 
11 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteAdenosine-5-monophosphate (5TMS)
analyte InChIInChI=1S/C25H54N5O7PSi5/c1-39(2,3)29-23-20-24(27-17-26-23)30(18-28-20)25-22(35-41(7,8)9)21(34-40(4,5)6)19(33-25)16-32-38(31,36-42(10,11)12)37-43(13,14)15/h17-19,21-22,25H,16H2,1-15H3,(H,26,27,29)/t19-,21-,22-,25-/m1/s1
analyte mass708.13
chromatogram3223BF16
citationSchauer N, Steinhauser D, Strelkov S, Schomburg D, Allison G, Moritz T, Lundgren K, Roessner-Tunali U, Forbes MG, Willmitzer L, Fernie AR, Kopka J (2005) FEBS Letters 579, 1332-1337
authorsKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date15 December 2003
metabolite roleMETB
retention time (sec)2,626.68
retention index (VAR5 method, n-alkanes C10–C36)3,055.3 (predicted, according to Strehmel, N. et.al)
base peak (m/z)73
maximal intensity999
mass-intensity-peaks cardinality205 intensities
minimal m/z43
maximal m/z583
download JCAMP DXSpectrumJcampDx.ashx?id=49fa5797-a871-44a0-a283-f9e037d035e2
download MSPSpectrumMsp.ashx?id=49fa5797-a871-44a0-a283-f9e037d035e2

GC-Method

nameM[2]
citationRoessner U, Wagner C, Kopka J, Trethewey RN, Willmitzer L (2000) Plant J 23, 131-142
attributetextdetails
deconvolutionAMDIS, National Institute of Standards and Technology, Gaithersburg, MD, USADIRECTION:Low to High; WIDTH: 20; SUBTRACTION: two; RESOLUTION: low; SENSITIVITY: low; SHAPE: low
derivatizationMEOX; TMSMethoxyamination:60min37°C; Trimethylsilylation:>45min37°C
detectorMS-Quadm/z = 35-600; scans:2/s; MD 800 Thermo-Finnigan, San Jose, CA, USA
extractionmethanol:water (4:1; v/v); 15min70°C 
ion sourceEI70eV
metabolic inactivationcut; liquid nitrogen; -80°C 
partitioningmethanol fraction of a methanol:water:chloroform (approx. 2:2:1, v/v/v) partitioning 
RIALKANEC12, C15, C19, C22, C28, C32, C36
separationGCCOLUMN:5%diphenyl-95%dimethylpolysiloxane (arylene), 30+10m, ID:0.25mm, DF:0.25microm, Rtx-5SilMS Integra-Guard, #NA (Restek, Bad Homburg, Germany); PROGRAM:iso1min70°C, ramp9°C/min, iso5min350°C; FLOW:Helium, 0.6ml/min; INJECTION:1microL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved
Top