GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Melezitose (11TMS)

 

Replica Mass Spectra of Melezitose (11TMS)

replicalib entry datedetectionmethodspecies
101 January 2002 MS-QuadM[2]Standard
219 July 2007 MS-TOFMDN35Reference Substance
319 December 2003 MS-QuadM[2]Standard
414 November 2003 MS-QuadM[2]Arabidopsis thaliana
501 February 2005 MS-TOFM[6]Reference Substance
611 September 2005  M[FAME4090]Standard
726 November 2004  M[FAME4090]Standard
801 February 2005 MS-TOFM[6]Reference Substance
1630 March 2011  Fiehn_GC_2010 
1025 January 2005 MS-TOFM[MOR] 
17 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteMelezitose (11TMS)
analyte InChIInChI=1S/C51H120O16Si11/c1-68(2,3)52-34-38-41(61-72(13,14)15)44(64-75(22,23)24)46(66-77(28,29)30)49(56-38)58-48-43(63-74(19,20)21)40(36-54-70(7,8)9)59-51(48,37-55-71(10,11)12)60-50-47(67-78(31,32)33)45(65-76(25,26)27)42(62-73(16,17)18)39(57-50)35-53-69(4,5)6/h38-50H,34-37H2,1-33H3
analyte mass1,298.43
chromatogram6046if_22
citation 
authorsBoelling C, Liebig F, Erban A, Kopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date19 July 2007
metabolite roleMETB
retention time (sec)1,880.24
retention index (VAR5 method, n-alkanes C10–C36)3,433.19 (observed)
base peak (m/z)73
maximal intensity219,314
mass-intensity-peaks cardinality890 intensities
minimal m/z45
maximal m/z1,000
download JCAMP DXSpectrumJcampDx.ashx?id=b264ffa7-b2da-4a46-9557-89519bcb29cf
download MSPSpectrumMsp.ashx?id=b264ffa7-b2da-4a46-9557-89519bcb29cf

GC-Method

nameVAR5
citationKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
attributetextdetails
deconvolutionChromaTOFOFFSET: "just above noise"; SMOOTHING: 20; PEAK WIDTH: 6; S/N: 2
derivatizationMEOX; TMSMETHOXYAMINATION: 90min at 30°C; TRIMETHYLSILYLATION: 30min at 37°C
detectorMS-TOFm/z = 70-600; scans:20/s; Pegasus III TOF mass spectrometer
extractionwater:chloroform (2:1; v/v) 15min at 70°C
gas chromatographAgilent GC 6890 
ion sourceEI70eV
mass spectrometry instrumentPegasus III TOF mass spectrometer 
metabolic inactivationshock-frozen in liquid nitrogen 
RIALKANEC10, C12, C15, C18, C19, C22, C28, C32, C36
separationGCCOLUMN:5%phenyl-95%dimethylpolysiloxane, 30+10m, ID:0.25mm, DF:0.25µm, 5PDM VF-5ms (Varian, Darmstadt, Germany); PROGRAM:iso1min 70°C, ramp 9°C/min, iso 5min 350°C; FLOW:Helium, 0.6mL/min; INJECTION:1µL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C
protocolpropertyvalue
extractionwater chloroform(2:1; v/v) 15min at 70°C
derivatizationderivatisationMETHOXYAMINATION, 90min at 30°C
derivatizationderivatisationTRIMETHYLSILYLATION, 30min at 37°C
separationIon source temperature250°C
separationColumn length30+10m (analytical column + guard column)
separationColumn inner diameter0.25mm
separationTemperature programisotherm 1min 70°C, ramp 9°C/min, isotherm 5min 350°C
ion sourceelectron ionization70eV
detectorLECO instrument modelPegasus III TOF mass spectrometer
detectorhighest observed m/zm/z = 600
detectorlowest observed m/zm/z = 70
detectorsampling frequency20 scans/s
detectormass analyzer typeMS-TOF
deconvolutionmoving average smoothing20
deconvolutionsoftwareChromaTOF
deconvolutionsignal-to-noise ratio2
RIRetention indexdecane
RIRetention indexdodecane
RIRetention indexpentadecane
RIRetention indexoctadecane
RIRetention indexnonadecane
RIRetention indexdocosane
RIRetention indexoctacosane
RIRetention indexdotriacontane
RIRetention indexhexatriacontane
ChromatographyChromatographyAgilent GC 6890

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved
Top