GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Galactose-6-phosphate (1MEOX) (6TMS) MP

 

Replica Mass Spectra of Galactose-6-phosphate (1MEOX) (6TMS) MP

replicalib entry datedetectionmethodspecies
112 May 2005  M[NIST] 
201 September 2001 MS-TOFM[EIGTMS]Saccharomyces cerevisiae
301 November 2001 MS-TOFM[EIGTMS]Standard
401 November 2001 MS-QuadM[2]Standard
4 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteGalactose-6-phosphate (1MEOX) (6TMS) MP
analyte InChIInChI=1S/C25H64NO9PSi6/c1-28-26-20-22(30-37(2,3)4)24(32-39(8,9)10)25(33-40(11,12)13)23(31-38(5,6)7)21-29-36(27,34-41(14,15)16)35-42(17,18)19/h20,22-25H,21H2,1-19H3/b26-20+/t22-,23+,24+,25-/m0/s1
analyte mass722.26
chromatogram6080if_26
citationNA
authorsErban A, Strehmel N, Kopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date19 April 2010
metabolite role 
retention time (sec)1,353.09
retention index (VAR5 method, n-alkanes C10–C36)2,316.45 (observed)
base peak (m/z)73
maximal intensity1,243,399
mass-intensity-peaks cardinality946 intensities
minimal m/z45
maximal m/z1,000
download JCAMP DXSpectrumJcampDx.ashx?id=dec13df0-4b74-4e69-a309-0e23ed8f0fd8
download MSPSpectrumMsp.ashx?id=dec13df0-4b74-4e69-a309-0e23ed8f0fd8

GC-Method

nameVAR5
citationKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
attributetextdetails
deconvolutionChromaTOFOFFSET: "just above noise"; SMOOTHING: 20; PEAK WIDTH: 6; S/N: 2
derivatizationMEOX; TMSMETHOXYAMINATION: 90min at 30°C; TRIMETHYLSILYLATION: 30min at 37°C
detectorMS-TOFm/z = 70-600; scans:20/s; Pegasus III TOF mass spectrometer
extractionwater:chloroform (2:1; v/v) 15min at 70°C
gas chromatographAgilent GC 6890 
ion sourceEI70eV
mass spectrometry instrumentPegasus III TOF mass spectrometer 
metabolic inactivationshock-frozen in liquid nitrogen 
RIALKANEC10, C12, C15, C18, C19, C22, C28, C32, C36
separationGCCOLUMN:5%phenyl-95%dimethylpolysiloxane, 30+10m, ID:0.25mm, DF:0.25µm, 5PDM VF-5ms (Varian, Darmstadt, Germany); PROGRAM:iso1min 70°C, ramp 9°C/min, iso 5min 350°C; FLOW:Helium, 0.6mL/min; INJECTION:1µL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C
protocolpropertyvalue
extractionwater chloroform(2:1; v/v) 15min at 70°C
derivatizationderivatisationMETHOXYAMINATION, 90min at 30°C
derivatizationderivatisationTRIMETHYLSILYLATION, 30min at 37°C
separationIon source temperature250°C
separationColumn length30+10m (analytical column + guard column)
separationColumn inner diameter0.25mm
separationTemperature programisotherm 1min 70°C, ramp 9°C/min, isotherm 5min 350°C
ion sourceelectron ionization70eV
detectorLECO instrument modelPegasus III TOF mass spectrometer
detectorhighest observed m/zm/z = 600
detectorlowest observed m/zm/z = 70
detectorsampling frequency20 scans/s
detectormass analyzer typeMS-TOF
deconvolutionmoving average smoothing20
deconvolutionsoftwareChromaTOF
deconvolutionsignal-to-noise ratio2
RIRetention indexdecane
RIRetention indexdodecane
RIRetention indexpentadecane
RIRetention indexoctadecane
RIRetention indexnonadecane
RIRetention indexdocosane
RIRetention indexoctacosane
RIRetention indexdotriacontane
RIRetention indexhexatriacontane
ChromatographyChromatographyAgilent GC 6890

comments on this mass spectrum

Post a Comment
Name:
 
Website:  
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved
Top