GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Alanine, 3-cyano- (2TMS)

 

Replica Mass Spectra of Alanine, 3-cyano- (2TMS)

replicalib entry datedetectionmethodspecies
119 July 2007 MS-TOFVAR5Reference Substance
728 August 2012  MassBank GC 2010 Tsujimoto 
630 March 2011  Fiehn_GC_2010 
401 May 2001 MS-TOFM[EIGTMS]Standard Addition
501 August 2001 MS-QuadM[2]Standard
5 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteAlanine, 3-cyano- (2TMS)
analyte InChIInChI=1S/C10H22N2O2Si2/c1-15(2,3)12-9(7-8-11)10(13)14-16(4,5)6/h9,12H,7H2,1-6H3/t9-/m0/s1
analyte mass258.47
chromatogram4096GX4
citation 
authorsKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date07 September 2004
metabolite roleMETB
retention time (sec)779.5
retention index (VAR5 method, n-alkanes C10–C36)1,368.23 (predicted, according to Strehmel, N. et.al)
base peak (m/z)73
maximal intensity999
mass-intensity-peaks cardinality79 intensities
minimal m/z70
maximal m/z306
download JCAMP DXSpectrumJcampDx.ashx?id=ea2bb0a2-2c16-4ccf-b678-699af9013f5e
download MSPSpectrumMsp.ashx?id=ea2bb0a2-2c16-4ccf-b678-699af9013f5e

GC-Method

nameM[6]
citationErban A, Schauer N, Fernie AR, Kopka J (2006) In: Weckwerth W (ed): Methods in Molecular Biology Vol., Humana Press Inc., Totowa, USA
attributetextdetails
deconvolutionChromaTOF V1.00 (Pegasus Driver 1.61), LECO, St. Joseph, MI, USAOFFSET:1_SMOOTHING:3_WIDTH:6_SN:>2
derivatizationMEOX; TMSMethoxyamination:90min40°C; Trimethylsilylation:45min40°C
detectorMS-TOFMZ:70-600; SCANS:20/s; Pegasus III TOF-MS; LECO, St. Joseph, MI, USA
extractionmethanol:water (4:1; v/v); 15min70°C 
ion sourceEI70eV
metabolic inactivationcut; liquid nitrogen; -80°C 
partitioningmethanol fraction of a methanol:water:chloroform (approx. 2:2:1, v/v/v) partitioning 
RIALKANEC12, C15, C18, C19, C22, C28, C32, C36
separationGCCOLUMN:5%diphenyl-95%dimethylpolysiloxane (arylene), 30+10m, ID:0.25mm, DF:0.25microm, Rtx-5SilMS Integra-Guard, #525560 (Restek, Bad Homburg, Germany); PROGRAM:iso1min70°C, ramp9°C/min, iso5min350°C; FLOW:Helium, 0.6ml/min; INJECTION:1microL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C