GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Sorbitol (6TMS)

 

Replica Mass Spectra of Sorbitol (6TMS)

replicalib entry datedetectionmethodspecies
126 November 2004  M[FAME4090]Standard
212 May 2005  M[NIST] 
401 July 2001 MS-QuadM[2]Standard
701 November 2001 MS-TOFM[EIGTMS]Corynebacterium glutamicum
901 May 2001 MS-TOFM[EIGTMS]Standard Addition
2728 August 2012  MassBank GC 2010 Tsujimoto 
1025 January 2005 MS-TOFM[MOR] 
2503 November 2010  Schomburg_GC_2010 
2805 June 2013  MRI_2013 
1101 February 2005 MS-TOFM[6]Reference Substance
21 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteSorbitol (6TMS)
analyte InChIInChI=1S/C24H62O6Si6/c1-31(2,3)25-19-21(27-33(7,8)9)23(29-35(13,14)15)24(30-36(16,17)18)22(28-34(10,11)12)20-26-32(4,5)6/h21-24H,19-20H2,1-18H3/t21-,22+,23-,24-/m1/s1
analyte mass615.26
chromatogram2236BN14
citationSchauer N, Steinhauser D, Strelkov S, Schomburg D, Allison G, Moritz T, Lundgren K, Roessner-Tunali U, Forbes MG, Willmitzer L, Fernie AR, Kopka J (2005) FEBS Letters 579, 1332-1337
authorsKopka J, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date01 August 2002
metabolite roleMETB
retention time (sec)1,698.96
retention index (VAR5 method, n-alkanes C10–C36)1,922.37 (predicted, according to Strehmel, N. et.al)
base peak (m/z)73
maximal intensity999
mass-intensity-peaks cardinality102 intensities
minimal m/z47
maximal m/z594
download JCAMP DXSpectrumJcampDx.ashx?id=efba5ea8-986e-4db2-b18f-18d6f5cfa422
download MSPSpectrumMsp.ashx?id=efba5ea8-986e-4db2-b18f-18d6f5cfa422

GC-Method

nameM[2]
citationRoessner U, Wagner C, Kopka J, Trethewey RN, Willmitzer L (2000) Plant J 23, 131-142
attributetextdetails
deconvolutionAMDIS, National Institute of Standards and Technology, Gaithersburg, MD, USADIRECTION:Low to High; WIDTH: 20; SUBTRACTION: two; RESOLUTION: low; SENSITIVITY: low; SHAPE: low
derivatizationMEOX; TMSMethoxyamination:60min37°C; Trimethylsilylation:>45min37°C
detectorMS-Quadm/z = 35-600; scans:2/s; MD 800 Thermo-Finnigan, San Jose, CA, USA
extractionmethanol:water (4:1; v/v); 15min70°C 
ion sourceEI70eV
metabolic inactivationcut; liquid nitrogen; -80°C 
partitioningmethanol fraction of a methanol:water:chloroform (approx. 2:2:1, v/v/v) partitioning 
RIALKANEC12, C15, C19, C22, C28, C32, C36
separationGCCOLUMN:5%diphenyl-95%dimethylpolysiloxane (arylene), 30+10m, ID:0.25mm, DF:0.25microm, Rtx-5SilMS Integra-Guard, #NA (Restek, Bad Homburg, Germany); PROGRAM:iso1min70°C, ramp9°C/min, iso5min350°C; FLOW:Helium, 0.6ml/min; INJECTION:1microL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved
Top