GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Threonine (3TMS)

 

Replica Mass Spectra of Threonine (3TMS)

replicalib entry datedetectionmethodspecies
101 August 2002 MS-QuadM[2]Lotus japonicus (Regel) K. Larsen
211 September 2005  M[FAME4090]Standard
312 October 2005 MS-TRAPM[BAR] 
523 August 2005  M[FAME4090] 
611 September 2005  M[FAME4090]Standard
801 May 2001 MS-TOFM[EIGTMS]Standard
3103 November 2010  Schomburg_GC_2010 
901 June 2001 MS-TOFM[EIGTMS]Reference Substance
1001 November 2001 MS-TOFM[EIGTMS]Corynebacterium glutamicum
1122 February 2005 MS-TOFM[STR] 
34 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteThreonine (3TMS)
analyte InChIInChI=1S/C13H33NO3Si3/c1-11(16-19(5,6)7)12(14-18(2,3)4)13(15)17-20(8,9)10/h11-12,14H,1-10H3/t11-,12+/m1/s1
analyte mass335.66
chromatogram4132GX23
citation 
authorsLiebig F, Erban A, Max Planck Institute of Molecular Plant Physiology, Department of Molecular Plant Physiology (Prof. Willmitzer L), Am Muehlenberg 1, D-14476 Golm, Germany
lib entry date01 February 2005
metabolite roleMETB
retention time (sec)799.74
retention index (VAR5 method, n-alkanes C10–C36)1,379.63 (predicted, according to Strehmel, N. et.al)
base peak (m/z)73
maximal intensity999
mass-intensity-peaks cardinality109 intensities
minimal m/z70
maximal m/z322
download JCAMP DXSpectrumJcampDx.ashx?id=a816840e-7603-44dd-b44a-21fb927d41c7
download MSPSpectrumMsp.ashx?id=a816840e-7603-44dd-b44a-21fb927d41c7

GC-Method

nameM[6]
citationErban A, Schauer N, Fernie AR, Kopka J (2006) In: Weckwerth W (ed): Methods in Molecular Biology Vol., Humana Press Inc., Totowa, USA
attributetextdetails
deconvolutionChromaTOF V1.00 (Pegasus Driver 1.61), LECO, St. Joseph, MI, USAOFFSET:1_SMOOTHING:3_WIDTH:6_SN:>2
derivatizationMEOX; TMSMethoxyamination:90min40°C; Trimethylsilylation:45min40°C
detectorMS-TOFMZ:70-600; SCANS:20/s; Pegasus III TOF-MS; LECO, St. Joseph, MI, USA
extractionmethanol:water (4:1; v/v); 15min70°C 
ion sourceEI70eV
metabolic inactivationcut; liquid nitrogen; -80°C 
partitioningmethanol fraction of a methanol:water:chloroform (approx. 2:2:1, v/v/v) partitioning 
RIALKANEC12, C15, C18, C19, C22, C28, C32, C36
separationGCCOLUMN:5%diphenyl-95%dimethylpolysiloxane (arylene), 30+10m, ID:0.25mm, DF:0.25microm, Rtx-5SilMS Integra-Guard, #525560 (Restek, Bad Homburg, Germany); PROGRAM:iso1min70°C, ramp9°C/min, iso5min350°C; FLOW:Helium, 0.6ml/min; INJECTION:1microL, splitless, 230°C; TRANSFER:250°C; IONSOURCE:250°C

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved
Top