GOLM METABOLOME DATABASE
How would you rate the quality of this mass spectrum?
poor, not helpful 
 outstanding, most helpful.
This spectrum was 0 times rated; on average=0.0

Glucose-6-phosphate (1MEOX) (6TMS) MP

 

Replica Mass Spectra of Glucose-6-phosphate (1MEOX) (6TMS) MP

replicalib entry datedetectionmethodspecies
112 June 2003 MS-QuadM[2]Arabidopsis thaliana
301 December 2003 MS-QuadM[2]Standard
412 May 2005  M[NIST] 
2705 June 2013  MRI_2013 
619 July 2007 MS-TOFVAR5Reference Substance
815 March 2005 MS-TOFM[6]Reference Substance
2430 March 2011  Fiehn_GC_2010 
901 October 2001 MS-TOFM[EIGTMS]Standard Addition
1001 January 2002 MS-TOFM[EIGTMS]Standard
2628 August 2012  MassBank GC 2010 Ara 
24 spectrum(a)
rotate: click+drag; translate: alt+click+drag; zoom: mousewheel; save: mol

Spectrum Details

analyteGlucose-6-phosphate (1MEOX) (6TMS) MP
analyte InChIInChI=1S/C25H64NO9PSi6/c1-28-26-20-22(30-37(2,3)4)24(32-39(8,9)10)25(33-40(11,12)13)23(31-38(5,6)7)21-29-36(27,34-41(14,15)16)35-42(17,18)19/h20,22-25H,21H2,1-19H3/b26-20+/t22-,23+,24+,25+/m0/s1
analyte mass722.26
chromatogramNA(_46)
citationStrelkov S, von Elstermann M, Schomburg D (2004) Biological Chemistry 385, 853-861
authorsStrelkov S, University of Cologne, CUBIC - Institute of Biochemistry, Department Prof. Schomburg, Zuelpicher Str. 47, D-50674 Cologne, Germany
lib entry date22 February 2005
metabolite roleMETB-METB
retention time (sec) 
retention index (VAR5 method, n-alkanes C10–C36)2,308.72 (predicted, according to Strehmel, N. et.al)
base peak (m/z)73
maximal intensity999
mass-intensity-peaks cardinality347 intensities
minimal m/z39
maximal m/z561
download JCAMP DXSpectrumJcampDx.ashx?id=6694114f-15c3-4569-ac59-2bdd9ad5fe93
download MSPSpectrumMsp.ashx?id=6694114f-15c3-4569-ac59-2bdd9ad5fe93

GC-Method

nameM[STR]
citationStrelkov S, von Elstermann M, Schomburg D (2004) Biological Chemistry 385, 853-861
attributetextdetails
detectorMS-TOF 
ion sourceEI70eV
RIALKANEC10, C12, C15, C19, C22, C28, C32, C36
separationGCDB-5MS column (30m x 0.25µm) from J&W Scientific (Folsom, USA)

comments on this mass spectrum

Post a Comment
Name:
 
Website:
Email:
Comments:
service last updated 31/08/2021 © 2008-2014 Golm Metabolome Database - All rights reserved